The manual is correct but is missing information for on how to access the regulator (planned update during 2026).


King synthetic (removal of stock necessary):

  • Remove the screw in the safety lever, pull the lever out from the stock.
  • Remove the two front screws in the stock by the charging inlet.
  • Remove the screw by the triggerguard.
  • Gently remove the stock from the action


The regulator is now accessible as in  the instructions in the manual. 


King GRS:


  • Remove the trigger guard (one screw), 

The regulator is now accessible as in the instructions in the manual(hex-key with ball end is needed).

If only regular hex-key is available you can remove the stock as explained for the synthetic version.